Safety Relay Unit

telemecanique

G9SA

The G9SA Series Offers a Complete Line-up of Compact Units. • Four kinds of 45-mm wide Units are available: A 3-pole model, a 5-pole model, and models with 3 poles and 2 OFF-delay poles, as well as a Two-hand Controller. Also available are 17.5-mm wide Expansion Units with 3 poles and 3 OFF-delay poles. • Simple expansion connection. • OFF-delay models have 15-step OFF-delay settings. • Conforms to EN ISO13849-1 (PLe/Safety Category 4). • Both DIN track mounting and screw mounting are possible.

Model
Brief Desription
 
Model
Brief Desription
 
G9SA-EX031-T015

With Off-Delay Output, 3PST-NO, Aux Contact: SPST-NC, Off-Delay Time: 15s

G9SA-EX031-T030

With Off-Delay Output, 3PST-NO, Aux Contact: SPST-NC, Off-Delay Time: 30s

G9SA-EX031-T075

With Off-Delay Output, 3PST-NO, Aux Contact: SPST-NC, Off-Delay Time: 7.5s

G9SA-EX301

Main Contact: 3PST-NO, Auxiliary Contact: SPST-NC,

Model
Brief Desription
 
Model
Brief Desription
 
G9SA-301 AC/DC24

Emergency Stop Unit, 24VAC/VDC, 1 or 2 channels, 3PST (NO), Aux Contact: SPST-NC

G9SA-301 AC100-240

Emergency Stop Unit, 100-240VAC,1 or 2 channels, 3PST (NO), Aux Contact: SPST-NC

G9SA-321-T075 AC/DC24

Emergency Stop Unit with Off-Delay Units, 24VAC/VDC, 1 / 2 ch, 3PST (NO), Aux Contact: SPST-NC, OFF-Delay Contact: DPST-NO (7.5s)

G9SA-321-T075 AC100-240

Emergency Stop Unit with Off-Delay Units,100-240VAC, 1 / 2 ch, 3PST (NO), Aux Contact: SPST-NC, OFF-Delay Contact: DPST-NO (7.5s)

G9SA-321-T15 AC/DC24

Emergency Stop Unit with Off-Delay Units, 24VAC/VDC, 1 / 2 ch, 3PST (NO), Aux Contact: SPST-NC, OFF-Delay Contact: DPST-NO (15s)

G9SA-321-T15 AC100-240

Emergency Stop Unit with Off-Delay Units, 100-240VAC, 1 / 2 ch, 3PST (NO), Aux Contact: SPST-NC, OFF-Delay Contact: DPST-NO (15s)

G9SA-321-T30 AC/DC24

Emergency Stop Unit with Off-Delay Units, 24VAC/VDC, 1 / 2 ch, 3PST (NO), Auxiliary Contact: SPST-NC, OFF-Delay Contact: DPST-NO (30s)

G9SA-321-T30 AC100-240

Emergency Stop Unit with Off-Delay Units, 100-240VAC, 1 / 2 chs, 3PST (NO), Auxiliary Contact: SPST-NC, OFF-Delay Contact: DPST-NO (30s)

G9SA-501 AC/DC24

Emergency Stop Unit, 24VAC/VDC, 1 or 2 channels, 5PST (NO), Aux Contact: SPST-NC

G9SA-501 AC100-240

Emergency Stop Unit, 100-240VAC, 1 or 2 channels, 5PST (NO), Aux Contact: SPST-NC

G9SA-TH301 AC/DC24

Two Hand Controller, 24VAC/VDC, 2 ch, 3PST (NO), Aux Contact: SPST-NC

G9SA-TH301 AC100-240

Two Hand Controller, 100-240VAC, 2 ch, 3PST (NO), Auxiliary Contact: SPST-NC